Temperature and humidity test chamber sudden failure effective solution

The constant temperature and humidity test chamber produced by our company is made of high-quality materials, processed using the most advanced processing equipment in the country, and the outer shell surface is spray-coated, beautiful and smooth. Coordinating color, angular design, smooth and natural lines. The liner is made of imported high quality stainless steel plate, with reasonable design and durability. Under the premise of meeting the national standards, the equipment is more practical and easy to control on the basis of stable performance in all aspects. In addition, the constant temperature and humidity test chamber has features such as easy installation and simple operation. The following is our company's introduction to the best solution to the customer's sudden failure when using the constant temperature and humidity test chamber, and we hope to help everyone;

First of all, take a look at the inspection steps: start by checking the under-water over-temperature protector in the control room to see if it is set at 150°C; if it is not set at 150°C, turn the under-water over-temperature protector To a position of 150°C;

In the inspection and inspection equipment room, whether the pipeline is too dirty and the water flow is not smooth; Solution: Please turn off the main power at the rear of the machine and then open the drain valve under the humidification tank to a position parallel to the pipeline. When the water in the tank is drained, use a wrench to open the humidifier barrel, remove the internal scale due to long-term humidity, remove the silicone tube, and wash it in the water. After the maintenance is complete, remove it in the opposite direction. After the device is completed, the drain valve below the humidifying tank needs to be closed to a position perpendicular to the pipeline, and then the main power supply at the rear of the platform is opened;

Look again at the water tank if there is water. If it is not water, check whether there is water in the water tank. Solution: The upper and lower water tanks are water-free. Please add water to the water tank. If the water tank is empty and the water tank has water, then the water pump for the water tank will be broken. Please inform Hongda Tianji Company to repair the customer service department for repair.

Finally, please check whether the solid state relay of the humidity part of the constant temperature and humidity test box is burned out. Short circuit: If the heater is not burned out, please use the three-purpose AC voltage file, and the voltage range should be opened to 600 volts to place the red and black bars separately. For the solid state relay on both sides of the AC marked with H on the line number, set the humidity value of the humidity part to 0%. At this time, the indicator of the solid state relay of the humidity part will not light, if the voltage value is measured. No change. Maintaining below 10V represents solid state relay burnout and short circuit. Or set the humidity section to 0% first, and then check whether the water in the engine room is boiled.